Index
A
A – Answer ................................................................. 7
\A – Select Maximum MNP Block Size..................... 17
A/ – Repeat Last Command ....................................... 7
Abort timer – S7 ....................................................... 38
Adaptive Answer Result Code – %A ........................ 20
Answer – A ................................................................. 7
Asynchronous Communications Mode – &Q ............ 16
Asynchronous Word Length – $EB .......................... 32
AT – Attention Code ................................................... 7
AT Command Control – %DC .................................. 21
AT commands
Definition ................................................................ 6
format ..................................................................... 6
Attention code – AT.................................................... 7
Automatic Hang-Up Control – +VNH ........................ 45
B
B – Communication Standard Setting ........................ 7
\B – Transmit Break ................................................. 18
Backspace character – S5 ....................................... 38
Beep Tone Duration Timer (DTMF/Tone Generation
Duration) – +VTD ................................................. 53
Bell 212A mode .......................................................... 7
Break Control – \K .................................................... 18
Break Handling in Error Control – +EB..................... 26
C
-C – Data Calling Tone ............................................. 20
Call Termination Buffer Management – +ETBM....... 27
Callback Attempts – #CBA ....................................... 36
Callback Delay – #CBD ............................................ 36
Callback Enable/Disable – #CBS ............................. 37
Callback Failed Attempts Display – #CBF? .............. 36
Callback Failed Attempts Reset – #CBFR ............... 36
Callback Parity – #CBP ............................................ 37
Callback Security Reset – #CBR.............................. 37
Caller ID Selection – +VCID ..................................... 35
Carriage return character – S3 ................................. 38
Carrier loss disconnect time – S10........................... 38
Command mode......................................................... 6
Command Speed Response – %S........................... 22
Command string ......................................................... 6
Communication Standard Setting – B ........................ 7
Complete List of Capabilities Request – +GCAP ..... 28
Connection Information Display ............................... 10
Count Rings – S1 ..................................................... 38
Countries or regions supported ................................ 62
Country Code Display .............................................. 10
Country of Installation – +GCI= ................................ 28
country/regional codes.............................................62
D
D – Dial ...................................................................... 8
Data buffering........................................................... 16
Data Calling Tone – -C ............................................. 20
Data Carrier Detect – &C ......................................... 14
Data Compression Control – %C ............................. 21
Data mode ................................................................. 6
Data Set Ready Control – &S .................................. 16
Dial – D ...................................................................... 8
Dialing tones – S11 .................................................. 38
Distinctive Ring (Ring Cadence Reporting) – +VDR 53
Distinctive Ring Report – +VDR ............................... 34
Downstream Data Rate – S38................................. 39
DTE/DCE Interface Rate (Turn Off Autobaud) – +VPR
............................................................................. 56
DTE/DCE Interface Rates ........................................ 61
DTE-DCE Local Flow Control – +IFC ....................... 29
DTE-DCE Local Rate Reporting – +ILRR ................ 29
DTR Control – &D .................................................... 14
DTR Dialing – $D ..................................................... 32
E
E – Echo Command ................................................... 9
Echo – E .................................................................... 9
Enable/Disable Voice Mode Packet Protocol – +VPP
............................................................................. 56
Enter key .................................................................... 7
Enter Setup Password – #S ..................................... 34
Enter Voice Receive State – +VRX .......................... 45
Error control – S36 ................................................... 38
Error control – S48 ................................................... 40
Error Control Report – +ER ...................................... 26
Error Control Selection – +ES .................................. 27
Error Correction Mode – \N ...................................... 19
Escape sequence....................................................... 6
Escape sequence – +++AT ........................................ 7
Escape Sequence – S2 ............................................ 38
Event Reporting and Masking – +VEM .................... 54
F
F – Online Data Character Echo ................................ 9
Fallback and Fall Forward – %E .............................. 21
Fax Class Indication – +FCLASS ............................. 28
Fax commands........................................................... 6
Firmware Version Display ........................................ 10
Fixed DTE Rate – +IPR............................................ 29
Flow Control ............................................................. 57
Flow Control Assert and Deassert Points – +VBT.... 55
Flow Control Selection – &K .................................... 15
H
H – Hook Control........................................................ 9
Hook Control – H........................................................ 9
I
I – Request ID Info ................................................... 10
Implements V.34 Handshake – $LL ......................... 32
Inactivity timer – S30 ................................................ 38
Inactivity Timer – \T .................................................. 19
Inactivity Timer – VIT ............................................... 48
Initialization strings ..................................................... 6
Initialize Voice Parameters – +VIP ........................... 45
K
\K – Break Control .................................................... 18
L
Leased Line Operation – &L .................................... 15
Line feed character – S4 .......................................... 38
Load Factory Settings – &F ...................................... 14
Local Callback Inactivity Timer – #CBI ..................... 36
Local Flow Control Selection – \Q ............................ 19
Long Break – $LB .................................................... 32
M
M – Monitor Speaker Mode ...................................... 10
Manufacturer Identification Request – +GMI ............ 28
Multi-Tech Systems, Inc. AT Commands for the MultiModem & SocketModem MT9234 Series (S000434H)
64
相关PDF资料
MT9234ZBA-USB MODEM V.92 DATA/FAX WORLD USB
MT9234ZPX-PCIE-CP MODEM V.92 DATA/FAX/VOICE WORLD
MT9M032I12STCH ES KIT HEAD BOARD FOR MT9M032
MT9T031P12STCH ES KIT HEAD BOARD FOR MT9T031
MT9V022I77ATMH ES KIT HEAD BOARD FOR MT9V022
MTCBA-C-N14-NAM MODEM CDMA RS-232 US ALLTEL
MTCBA-EN-AK-EU/GB KIT ACCY FOR ETH MODEMS EU/GB
MTFDDAA512MAM-1K1 SSD 1.8" SATA 512GB
相关代理商/技术参数
MT9234ZBA-V-EU 功能描述:MODEM V.92 DATA/FAX/VOICE WORLD RoHS:是 类别:计算机,办公室 - 元件,配件 >> 调制解调器 系列:MultiModem® ZBA 标准包装:1 系列:MultiModem® ZBA 数据格式:V.34,V.92 波特率:- 电源电压:- 安装类型:台式 封装/外壳:5.7" L x 4.3" W x 1.0" H(145mm x 109mm x 25mm) 供应商设备封装:- 包装:散装
MT9234ZBA-V-GB/IE 功能描述:MODEM V.92 DATA/FAX/VOICE WORLD RoHS:是 类别:计算机,办公室 - 元件,配件 >> 调制解调器 系列:MultiModem® ZBA 标准包装:1 系列:MultiModem® ZBA 数据格式:V.34,V.92 波特率:- 电源电压:- 安装类型:台式 封装/外壳:5.7" L x 4.3" W x 1.0" H(145mm x 109mm x 25mm) 供应商设备封装:- 包装:散装
MT9234ZBA-V-IEC 功能描述:MODEM V.92 DATA/FAX/VOICE WORLD RoHS:是 类别:计算机,办公室 - 元件,配件 >> 调制解调器 系列:MultiModem® ZBA 标准包装:1 系列:MultiModem® ZBA 数据格式:V.34,V.92 波特率:- 电源电压:- 安装类型:台式 封装/外壳:5.7" L x 4.3" W x 1.0" H(145mm x 109mm x 25mm) 供应商设备封装:- 包装:散装
MT9234ZBA-V-NAM 功能描述:MODEM V.92 DATA/FAX/VOICE WORLD RoHS:是 类别:计算机,办公室 - 元件,配件 >> 调制解调器 系列:MultiModem® ZBA 标准包装:1 系列:MultiModem® ZBA 数据格式:V.34,V.92 波特率:- 电源电压:- 安装类型:台式 封装/外壳:5.7" L x 4.3" W x 1.0" H(145mm x 109mm x 25mm) 供应商设备封装:- 包装:散装
MT9234ZBA-V-NPS-CP 制造商:Multi-Tech Systems 功能描述:V.92 VOICE/DATA/FAX WORLD MODEM (NO POWER SUPPLY) (25 MODEMS - Bulk
MT9234ZPX-PCIE 功能描述:MODEM V.92 WORLD PCI EXPRESS RoHS:是 类别:计算机,办公室 - 元件,配件 >> 调制解调器 系列:MultiModem® ZPX 标准包装:1 系列:MultiModem® ZBA 数据格式:V.34,V.92 波特率:- 电源电压:- 安装类型:台式 封装/外壳:5.7" L x 4.3" W x 1.0" H(145mm x 109mm x 25mm) 供应商设备封装:- 包装:散装
MT9234ZPX-PCIE-CP 功能描述:MODEM V.92 DATA/FAX/VOICE WORLD RoHS:是 类别:计算机,办公室 - 元件,配件 >> 调制解调器 系列:MultiModem® ZPX 标准包装:1 系列:MultiModem® ZBA 数据格式:V.34,V.92 波特率:- 电源电压:- 安装类型:台式 封装/外壳:5.7" L x 4.3" W x 1.0" H(145mm x 109mm x 25mm) 供应商设备封装:- 包装:散装
MT9234ZPX-PCIE-NV 制造商:Multi-Tech Systems 功能描述:V.92 DATA/V.34 FAX WORLD MODEM (PCI EXPRESS) - Bulk